VAHLE Safe Application Control Systems – VCS-SMG-SAFE and VCS-PCB-SAFE

VAHLE VCS-SMG-SAFE and VCS-PCB-SAFE safe control systems provide a high level of functional safety on intralogistics and automotive production lines.
With their TÜV-certified design, they easily implement safe speed, safe position and fail-safe control functions.
Thanks to PROFIsafe communication, encoder support and SMGM waveguide-based data transmission, they deliver fully reliable performance.

  • TÜV-certified safe control system
  • Easy configuration via function block
  • Fully compatible with the VCSX control system
  • Predefined technology applications ready integrated
  • Easy device replacement thanks to an integrated memory card
  • Transparent, reliable structure based on SMGM and Rail Bus technology
Categories: ,

Description

VAHLE Safe Application Control Systems – VCS-SMG-SAFE and VCS-PCB-SAFE

VAHLE VCS-SMG-SAFE & VCS-PCB-SAFE – Safe Application Control Systems

Today, intralogistics and automotive production applications run with a high degree of automation. As the flexibility requirements of plants grow ever more complex, new challenges arise for logistics planners and system integrators. Functional safety plays an increasingly important role in modern machine and plant design. Safe shutdown is critical not only for protecting personnel but also for preventing interruptions in the production process.

The TÜV-approved VCS-SMG-SAFE and VCS-PCB-SAFE safe application control systems work in full harmony with VCSX drive control units, allowing predefined safety functions to be commissioned quickly and easily. These safety modules come pre-configured with application-specific, fail-safe configurations. Safe control and monitoring of the drive technology is handled entirely by the VCS-SMG-SAFE or VCS-PCB-SAFE units.

Encoder-supported safety functions — such as Safely Limited Speed (SLS) or Safe Position (SPOS) — can be easily implemented, especially in applications like electrified monorail systems. System parameters can be flexibly adapted to field conditions, so no complex programming is needed in the plant PLC; data exchange is reduced to the transmission of process and diagnostic data only.

Offering Safe Input support for safe switching between manual and automatic operation, the systems are also equipped with 1 HTL and 1 SSI encoder interface. In the VCS-SMG-SAFE version, communication with the plant PLC and the VCSX drive control unit is carried out via the PROFIsafe protocol, and data transmission between the fixed and moving sides is provided by the SMGM Slotted Microwave Guide system, which is completely immune to electromagnetic interference. In the VCS-PCB-SAFE version, all safety evaluations are performed directly and exclusively on the moving side.

Used together with Drive Control, Power Transmission, Positioning and Data Communication Systems modules, the VCS-SMG-SAFE and VCS-PCB-SAFE systems form part of VAHLE’s integrated system solution.

svg+xml;charset=utf

VCS-SMG-SAFE

svg+xml;charset=utf

VCS-PCB-SAFE

Technical Data – Electrical Properties

Specification VCS-SMG-SAFE VCS-PCB-SAFE
Besleme gerilimi 24 VDC ±10 % (SELV / PELV) 24 VDC ±10 % (SELV / PELV)
Power consumption < 13 W < 13 W
Current consumption without encoder < 600 mA < 600 mA

Technical Data – Mechanical Properties

Specification VCS-SMG-SAFE VCS-PCB-SAFE
Dimensions (mm) 203 × 128 × 128 203 × 128 × 128
Protection class IP54 IP54
Housing material Alüminyum Alüminyum

Technical Data – System Properties

Specification VCS-SMG-SAFE VCS-PCB-SAFE
Data transmission (fixed / mobile) SMG interface (HF) Rail Bus
Transmission medium (fixed / mobile) VAHLE Slotted Microwave Guide (SMGM) VAHLE Conductor System
Desteklenen fieldbus protokolleri PROFINET / PROFIsafe, VAHLE System CANbus PROFINET / PROFIsafe, VAHLE System CANbus
Supported safety functions STO, SBC, SS1/SS2, SLS, SCA, SBT, SDI, SPOS, SD STO, SBC, SS1/SS2, SLS, SCA, SBT, SDI, SPOS, SD
Güvenlik bütünlük seviyesi (IEC 61508) Maks. SIL 3 Maks. SIL 3
Performans seviyesi (EN ISO 13849-1) Maks. PL e / Kat. 4 Maks. PL e / Kat. 4
Encoder interface – safe encoders PROFIsafe PROFIsafe
Encoder interface – non-safe encoders 1× HTL / 1× SSI 1× HTL / 1× SSI
Safe input (2-channel)
Clock outputs

Operating Conditions

Specification VCS-SMG-SAFE VCS-PCB-SAFE
Operating temperature 0°C to +50°C 0°C to +50°C
Application area Indoor systems Indoor systems

Catalogs and Brochures

User and Installation Manuals

Get a Quote Tailored to Your Needs!

Fill in the short form and our team will quickly get back to you with a project-specific solution and delivery time.